Looking to buy TAPCON ISM TECHNOLOGY TAPCON® TOPO by Tapcon in the United States? At PAOParts LLC, we offer a wide range of industrial products, including TAPCON ISM TECHNOLOGY TAPCON® TOPO. Whether you're located in Houston, Austin, San Antonio, Fort Worth, Dallas, Los Angeles, San Diego, Salt Lake City, Kansas City, Seattle, Miami, Detroit, New York City, Chicago, or Denver, we can supply the Tapcon products you need.
TAPCON ISM TECHNOLOGY TAPCON® TOPO
If you need more information about TAPCON ISM TECHNOLOGY TAPCON® TOPO, please contact us for details.
As an independent supplier, we provide genuine Tapcon products at competitive prices. Our efficient distribution network ensures prompt delivery across the USA. We source our products from trusted channels, so you can be confident in the authenticity and quality of the items you purchase from us.
Ready to purchase or need more details about TAPCON ISM TECHNOLOGY TAPCON® TOPO? Reach out to us today. Call +1 417 261 6001 or email sales@paoparts.com. Our expert team is here to assist you in finding the perfect solutions for your industrial needs.
PAOParts LLC is an independent supplier of Tapcon products and is not affiliated with or authorized by the official distributor. All trademarks and brand names are the property of their respective owners.
For customized pricing and availability, please fill out ourcontact formor give us a call. We are dedicated to providing solutions that align with your specific requirements.
How can I access TAPCON ISM TECHNOLOGY TAPCON® TOPO catalogs, user manuals, technical documents, and PDFs?
Do you provide technical support for TAPCON ISM TECHNOLOGY TAPCON® TOPO?
While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.
| Manufacturer | Tapcon |
|---|---|
| Country | |
| Part number | TAPCON ISM TECHNOLOGY TAPCON® TOPO |
| Inner Code | 4947140 |
| Custom Code | 85371098 |
| Housing variant 19" housing (84HPx3HU) Display HMI front assembly Full graphics 5.7" color display, 640 x 480 pixels Operation via cursor wheel and function keys RJ45 front interface for setting device parameters using PC/laptop Internal power supply 24 VDC Supply voltage 85-265V AC/DC Un 100-240V AC Un 107-240V DC Product description Automatic voltage regulator for regulating, controlling, and monitoring regulated power transformer in 19" racks in accordance with DIN 41494 Part 5 (W x H x D 483 x 133 x 178 mm; 84HPx3HU). Modular hardware equipment, basic equipment consisting of: CPU (central processing unit) I Communication interfaces: 3 x RJ45 SCADA/device parameter setting (local & remote) 1 x RS232 System interface 1 x RS232/422/485 Control center communication 2 x CAN Parallel operation communication and decentralized I/O modules 1 x USB Firmware/software/database upload and download Operation Operating modes: Local and Remote Control function: AVR Manual and AVR Auto Full graphics, web-based visualization on the device and PC/laptop with intuitive operator guidance and navigation, including help function. Commissioning wizard for assisted initial parameterization. Documentation available as PDF file on the device. Safety Role-based user management Encrypted data transmission (SSL) to visualize and upload/download data and parameters Adjustable variables Voltage regulation for regulated power transformers Additional function Function description Regulation with linear or integral T1 and T2 time delay (setting range T1: 0 600s; T2: 1...10 s) Line drop compensation (R&X compensation or Z compensation) Control function: AVR Manual and AVR Auto Monitoring functions Bandwidth monitoring Function monitoring Limit value monitoring Voltage U<<, U<, U>, U>> Current I<<, I<, I>, I>> Power S<<, S<, S>, S>>, P<<, P<, P>, P>>, Q<<, Q<, Q>, Q>> Phase angle cos <, cos << 4 adjustable limit values, including hysteresis and time delay for all analog values Digital input/output module Digital input/output module DIO 42-20 42 electrically isolated wide-range inputs 12 electrically isolated changeover relay contact (AC: 230 V/5 A; DC: 250 V/250 mA) 8 electrically isolated relay make contacts (AC: 230 V/5 A; DC: 250 V/250 mA) Switching level DIO 18V Power measuring module Power measuring module UI 1 Single-phase voltage and current measurement Un: 100 V AC; Measurement range: 20...190 V AC, f: 45...65 Hz In: 0.2/1/5 A AC; Measurement range: 1...210% In, f: 45...65 Hz Tap position capture BCD Tap position output via BCD with Set. the des. volt. lev. rem. 3 desired values Parallel operation CAN bus (retrofit Detection parallel operation Special topology with flexible master/client function: Recording the position of up to 24 circuit breakers and forwarding of parallel operation status by CAN bus. Every device records the status of the circuit breakers via digital inputs. The device with the lowest CAN bus address operates as the topology master. Can-Bus plug with User IO Mapping with | |
| default.weight_all_offices | 5 |
|---|