The ADOX 592 TOX CO sensor is designed for measuring the concentration of toxic carbon monoxide gases utilizing an electro-chemical reaction measuring principle. It features standard measuring ranges of 0–150 ppm and 0–300 ppm, with other ranges available on request. Designed for reliable performance, the unit delivers a response time (t90) of under 60 seconds and includes an integrated filter that maintains cross sensitivity at less than 2%. Communication is handled via a galvanically isolated 2-wire current interface of 4–20 mA or LON four-wire techniques with a 78 kbps data transmission rate. Operating within an ambient temperature range of -10°C to 40°C supported by sensor temperature compensation, and a non-condensing humidity range of 10–99%, the sensor includes test certification to German standards according to VDI 2053 when used in conjunction with the ADOS MULTITRONIK 592. The serviceable life of the cell is approximately 2 years, and the sensor dimensions are 80 mm in diameter and 80 mm in height.
For customized pricing and availability, please fill out ourcontact formor give us a call. We are dedicated to providing solutions that align with your specific requirements.
How can I access ADOX 592 TOX CO same as ADOS 592 TOX CO catalogs, user manuals, technical documents, and PDFs?
Do you provide technical support for ADOX 592 TOX CO same as ADOS 592 TOX CO?
While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.
| Manufacturer | Ados |
|---|---|
| Country | |
| Part number | ADOX 592 TOX CO same as ADOS 592 TOX CO |
| Inner Code | 1183570 |
| Product type | Toxic Gas Sensor for Carbon Monoxide |
|---|---|
| Measuring principle | Electro-chemical reaction |
| Measurable substance | Carbon monoxide |
| Measuring ranges | 0–150 ppm, 0–300 ppm |
| Zero error | < 10 ppm CO |
| Reading instability | < 3 ppm CO |
| Accuracy | ± 3 % of f.s.d |
| Zero drift | < 2 % per year |
| Repeatability | < 2 % per year |
| Linearity | < 2 % of f.s.d |
| Response time (t90) | < 60 sec. |
| Cross sensitivity | < 2 % with integrated filter |
| Interface | 2-wire current interface 4–20 mA or LON® four-wire techniques, galvanically isolated, data transmission 78 kbps |
| Supply voltage | 15 V–30 V, dependent on maximum load 100 ohm–500 ohm |
| Ambient temperature | - 10°C to 40°C, with sensor temperature compensation |
| Humidity range | 10–99 %, non-condensing |
| Serviceable life of cell | Approx. 2 years |
| Sensor dimensions | Diameter 80 mm, Height 80 mm |
| Test certificate | To German standards, according to VDI 2053 in conjunction with ADOS MULTITRONIK 592 |