The Airflow 22495 VOC Air Quality Probe 985 is a specialized sensor designed for measuring volatile organic compounds in ppm alongside temperature. This probe provides a VOC measurement range of 1 to 2000 ppm with a 1 ppm resolution. The accuracy for VOC is specified at ± 3 % of the measured value plus ± 50 ppm at 25°C and 1013 mbar, with a temperature coefficient of ± 0.36 % of the measured value per °C. Additionally, the integrated temperature measurement covers a range of -10 to 60°C with an accuracy of ± 0.5 °C. This dual-measurement capability makes the Airflow 22495 essential for monitoring environmental air quality and thermal conditions within its operational limits.
For customized pricing and availability, please fill out ourcontact formor give us a call. We are dedicated to providing solutions that align with your specific requirements.
How can I access 22495 catalogs, user manuals, technical documents, and PDFs?
Do you provide technical support for 22495?
While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.
| Manufacturer | Airflow |
|---|---|
| Country | |
| Part number | 22495 |
| Inner Code | 3433061 |
| Product type | VOC air quality probe |
|---|---|
| VOC measurement range | 1 - 2000 ppm |
| VOC resolution | 1 ppm |
| VOC accuracy | ± 3 % of measured value ± 50 ppm at 25°C and 1013 mbar |
| VOC temperature coefficient | ± 0.36 % of measured value/°C |
| Temperature measurement range | -10 - 60°C |
| Temperature accuracy | ± 0,5 °C |