The Conatex sheath thermocouple (Part Numbers T560K126AL2500mm227X and T033484) is a Form 6 temperature measurement assembly featuring a NiCr-Ni (Type K) thermopair material with a single thermopair. Designed with a 2500 mm length L and a 3.0 mm mantle diameter, it utilizes an Inconel 2.4816 sheath material for durability. The measurement point is insulated against the jacket (A). For electrical connection, it is equipped with a LEMO connector (RC type, size 2, 2-pin) with the positive pole on the pin. Additionally, it includes a loosely enclosed LEMO plug of type F, size 2, 2-pin, featuring a cable clamp for 3.0-4.0 mm cables. This component conforms to Tolerance class 1 according to DIN EN 60584-2.
For customized pricing and availability, please fill out ourcontact formor give us a call. We are dedicated to providing solutions that align with your specific requirements.
How can I access T560K126AL2500mm227X / T033484 catalogs, user manuals, technical documents, and PDFs?
Do you provide technical support for T560K126AL2500mm227X / T033484?
While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.
| Manufacturer | Conatex |
|---|---|
| Country | |
| Part number | T560K126AL2500mm227X / T033484 |
| Inner Code | 5080635 |
| Product type | Form 6 Sheath Thermocouple |
|---|---|
| Form | Form 6 |
| LEMO connector | RC type, size 2, 2-pin |
| Polarity | positive pole on the pin |
| Thermopair material | NiCr-Ni (K) |
| Number of thermopairs | 1 |
| Sheath material | Inconel 2.4816 |
| Mantle diameter | 3.0 mm |
| Measurement point | insulated against the jacket (A) |
| Length L | 2500 mm |
| Tolerance class | 1 DIN EN 60584-2 |
| Special features | LEMO plug, type F, size 2, 2-pin, with cable clamp 3.0-4.0 mm, Loosely enclosed |
| Order number | T560k126al2500mm227x |