The MSA part number 10112334 19 1603 1127 is an explosion-protected PrimaX P HART-EX transmitter housed in a robust powder-coated aluminum junction enclosure designed for monitoring hydrogen sulfide (H2S) in air. Operating on an electrochemical measuring cell principle, this unit is factory-calibrated for H2S with a measuring range of 0 to 50 ppm, alongside adjustable ranges of 0 to 10 ppm, 0 to 20 ppm, and 0 to 100 ppm configurable via the control panel. It features a built-in LCD display, 3-wire wiring, outputs for 4 to 20 mA, alarm relays, and fault relays, plus an intrinsically safe HART interface utilizing the digital HART protocol for evaluation and configuration. The device includes preset alarms and operates on a typical power consumption of 24 VDC at 3 W. Certified for hazardous locations under ATEX and IECEx standards, the unit measures 220 x 162 x 100 mm, weighs 1.6 kg, and comes supplied with a nickel-plated brass M25x1.5 mm Ex d cable gland, splash guard, and calibration cap.

More Msa part numbers

See all Msa products

Frequently Asked Questions(FAQ):


Where can I buy 10112334 19 1603 1127 by Msa in the USA?

You can purchase 10112334 19 1603 1127 by Msa from PAOParts LLC. We serve customers across the USA, offering competitive prices and reliable service.


What is the price of the 10112334 19 1603 1127?

Price and availability are quoted per request. Send the part number and the quantity you need through our quote request form and you will receive a written offer by e-mail.


Who is the official distributor or seller of Msa in the United States?

While we are not the official distributor or seller of Msa in the United States, we source our products from reliable channels and offer you original Msa equipment at competitive prices.


How can I access 10112334 19 1603 1127 catalogs, user manuals, technical documents, and PDFs?

Ask for them in your quote request. We attach the datasheet, catalogue page or manual we hold for 10112334 19 1603 1127 to our written reply.


Do you provide technical support for 10112334 19 1603 1127?

While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.

Characteristics

Manufacturer Msa
Part number 10112334 19 1603 1127
Inner Code 589095

Technical specification

Product type Explosion-Protected HART-EX Transmitter
Manufacturer MSA
Part Number 10112334 19 1603 1127
Model PrimaX P, M25, H+R, H2S 50
Enclosure Material Powder-coated aluminum
ATEX Protection Class Gas II 2G Ex d ia [ia] IIC T4 Gb
ATEX Protection Class Dust II 2D Ex tb ia [ia] IIIC T130°C Db IP67
Ambient Temperature Range ATEX -40°C to +55°C (Ox-Tox-Sensor +70°C)
Type Examination Certificate Number BVS 10 ATEX E 009 X
IECEx Certificate Number IECEx BVS 10.0063X N1
Enclosure Protection Class IP 66
Measuring Principle Electrochemical measuring cell
Calibrated Gas Hydrogen sulfide (H2S) in air
Measuring Range 0...50 ppm
Transmitter Alarm 30 % of measuring range
Evaluation Unit Alarm 1 5 ppm
Evaluation Unit Alarm 2 10 ppm
Configurable Measuring Ranges 0...10 ppm, 0...20 ppm, 0...100 ppm
Display LCD
Outputs 4...20 mA, Alarm relay, Fault relay
Interface Intrinsically safe HART interface, digital HART protocol
Wiring 3-wire
Permissible Ambient Temperature Range -40...+50°C
Relative Humidity 15...90% non-condensing
Pressure Range 80...120 kPa
Power Consumption 24 VDC / 3 W typical
Dimensions (H x W x D) 220 x 162 x 100 mm
Weight 1.6 kg
Included Items Cable gland M25x1.5 mm Ex d 9-16 mm Brass nickel-plated, Splash protection, Calibration cap