09027-M by PRO-CHEM
Get a quote
The PRO-CHEM 09027-M is an explosion-protected oxygen transmitter featuring ATEX 1/2 G Ex ia IIC T4 certification for hazardous environments. Designed for precise oxygen monitoring, it offers a measurement range of 0 to 5 percent O2 with a 0.1 ppm display resolution. The unit supports calibration using either ambient air or calibration gas. It delivers a fast response time of under 15 seconds for T90 at 25 degrees Celsius. The instrument operates within a working temperature range of 0 to 50 degrees Celsius and handles sample pressures from 0.1 to 1 bar. For system integration, the 09027-M provides a 4 to 20 mA signal output, powered by a 10 to 35 VDC voltage supply with a typical load of 470 ohms and a maximum of 1500 ohms. Data and status are visualized via a 6-digit display equipped with a bar graph.
More PRO-CHEM part numbers
Frequently Asked Questions(FAQ):
Where can I buy 09027-M by PRO-CHEM in the USA?
You can purchase 09027-M by PRO-CHEM from PAOParts LLC. We serve customers across the USA, offering competitive prices and reliable service.
What is the price of the 09027-M?
Price and availability are quoted per request. Send the part number and the quantity you need through our quote request form and you will receive a written offer by e-mail.
Who is the official distributor or seller of PRO-CHEM in the United States?
While we are not the official distributor or seller of PRO-CHEM in the United States, we source our products from reliable channels and offer you original PRO-CHEM equipment at competitive prices.
How can I access 09027-M catalogs, user manuals, technical documents, and PDFs?
Ask for them in your quote request. We attach the datasheet, catalogue page or manual we hold for 09027-M to our written reply.
Do you provide technical support for 09027-M?
While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.
Characteristics
| Manufacturer | PRO-CHEM |
|---|---|
| Part number | 09027-M |
| Inner Code | 4014992 |
| Custom Code | 90271010 |
Technical specification
| Product type | Ex-Protected Oxygen Transmitter |
|---|---|
| Ex Protection | ATEX 1/2 G Ex ia IIC T4 |
| Measurement range | 0 - 5% O2 |
| Calibration | with calibration gas / ambient air |
| Measurement uncertainty | +/- 2% MW T = const.+/- 5% MW 0> T> 50 ° C; min |
| Resolution | 0.1 ppm display |
| Response time | T90 at 25 ° C <15 s |
| Working temperature | 0 - 50 ° C |
| Sample pressure | 0.1 - 1 bar |
| Signal output | 4 -20 mA |
| Voltage | 10 - 35 VDC |
| Load | typ. 470 Ohm, max. 1500 ohms |
| Display | 6 digits, bar graph display |