367-010-040001 HF - Direct Driven Centrifugal Fan by Hurner Funken
Get a quote
The Hurner Funken direct driven centrifugal fan, part number 367-010-040001 (Type HF R 75-16 D/DS), is engineered for air handling applications with a volume flow of 100 m³/h. Manufactured by HLU, this unit features a PPs housing and a PP-el impeller, with a 75 mm suction diameter and case position GL 360**. Designed for an operating speed of 2825 rpm and a 50 Hz frequency, it delivers a total pressure difference of 244 Pa and a static pressure difference of 213 Pa. The fan is powered by a 0.18 kW motor operating at 3~ 230/400 V and 0.62 A, featuring IP 55 protection and an Ex classification of e II 2G Ex eb IIC T4 Gb. It operates within a media temperature range of 0 to 40 °C, with a sound pressure level of 56 dB(A) at 1 meter.
More Hurner Funken part numbers
See all Hurner Funken products
Frequently Asked Questions(FAQ):
Where can I buy 367-010-040001 by Hurner Funken in the USA?
You can purchase 367-010-040001 by Hurner Funken from PAOParts LLC. We serve customers across the USA, offering competitive prices and reliable service.
What is the price of the 367-010-040001?
Price and availability are quoted per request. Send the part number and the quantity you need through our quote request form and you will receive a written offer by e-mail.
Who is the official distributor or seller of Hurner Funken in the United States?
While we are not the official distributor or seller of Hurner Funken in the United States, we source our products from reliable channels and offer you original Hurner Funken equipment at competitive prices.
How can I access 367-010-040001 catalogs, user manuals, technical documents, and PDFs?
Ask for them in your quote request. We attach the datasheet, catalogue page or manual we hold for 367-010-040001 to our written reply.
Do you provide technical support for 367-010-040001?
While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.
Characteristics
| Manufacturer | Hurner Funken |
|---|---|
| Part number | 367-010-040001 |
| Inner Code | 4254936 |
Technical specification
| Product type | HF Direct Driven Centrifugal Fan |
|---|---|
| Brand | HLU |
| Type | HF R 75-16 D/DS |
| Housing material | PPs |
| Impeller material | PP-el |
| Case Position | GL 360** |
| Suction diameter | 75 mm |
| Pumped medium | Air |
| Ambient pressure | 101,325 kPa |
| Media temperature | 20 °C |
| Absorbent media density | 1,202 kg/m³ |
| Volume flow | 100 m³/h |
| Total pressure difference | 244 Pa |
| Static pressure difference | 213 Pa |
| Operating speed | 2825 rpm |
| max. perl Speed of the impeller | 3591 rpm |
| pergil. Media temperature range | 0/40 °C |
| Operating frequency | 50 Hz |
| Inlet velocity | 7.2 m/s |
| circumferential speed | 18.5 m/s |
| Sound pressure level Lp2A (1 m) | 56 dB (A) |
| Sound pressure level Lp2A (1 m) * | 61 dB (A) |
| Sound power level Lw6A | 65 dB (A) |
| Impeller Efficiency | 42.5% |
| SFP | 1023 [3] W/ (m³/s) |
| Power requirement for shaft | 0,016 kW |
| Engine power | 0.18 kW |
| Speed - Engine | 2825 1/min |
| Voltage | 3~ 230/400 V |
| Frequency | 50 Hz |
| Rated current | 0.62 A |
| Design | IM B34 C80/63A |
| Protection type/motor protection | IP 55/- |
| Ex classification | e II 2G Ex eb IIC T4 Gb |
| Motor suitable for FU | No |
| Temperature class | T3 (200 °C) |
| Requirement OUTSIDE | Category 3 (Zone 2) |