DLA2-12D3 by Citel
Get a quote
The Citel DLA2-12D3 is a 4-pole combined surge arrester utilizing diode and gas discharge tube technology, specifically designed for RS485 and RS232 applications. This plug-in unit features installation dimensions of 1 TE and weighs 0.1 kg per piece. Classified as a Type C2 and D1 arrester, it operates with a nominal voltage of 12 V and a C3 protection level of 30 V. The device handles a D1 lightning impulse current of 5 kA using a 10/350µs waveform, a C2 nominal discharge current of 5 kA, and a maximum discharge current of 20 kA based on an 8/20µs waveform. Additionally, the component offers a capacitance of less than 25 pF and a fast response time of under 1 ns. This model does not include a remote signaling contact.
More Citel part numbers
Frequently Asked Questions(FAQ):
Where can I buy DLA2-12D3 by Citel in the USA?
You can purchase DLA2-12D3 by Citel from PAOParts LLC. We serve customers across the USA, offering competitive prices and reliable service.
What is the price of the DLA2-12D3?
Price and availability are quoted per request. Send the part number and the quantity you need through our quote request form and you will receive a written offer by e-mail.
Who is the official distributor or seller of Citel in the United States?
While we are not the official distributor or seller of Citel in the United States, we source our products from reliable channels and offer you original Citel equipment at competitive prices.
How can I access DLA2-12D3 catalogs, user manuals, technical documents, and PDFs?
Ask for them in your quote request. We attach the datasheet, catalogue page or manual we hold for DLA2-12D3 to our written reply.
Do you provide technical support for DLA2-12D3?
While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.
Characteristics
| Manufacturer | Citel |
|---|---|
| Part number | DLA2-12D3 |
| Inner Code | 3285544 |
Technical specification
| Product type | 4-pole combined surge arrester |
|---|---|
| Part number | 640211 |
| Catalogue title | DLA2-12D3 |
| Technology | Diode - gas discharge tube technology |
| Applications | RS485 and RS232 |
| Arrester type | Typ C2, D1 |
| Nominal voltage Un | 12 V |
| C3 protection level Up | 30 V |
| D1 lightning impulse current Iimp | 5 kA (10/350µs) |
| C2 nominal discharge current In | 5 kA (8/20μs) |
| Max. discharge current Imax | 20 kA (8/20μs) |
| Capacitance C | <25 pF |
| Response time | <1 ns |
| Installation dimensions | 1 TE, plug-in |
| Remote signaling contact | none |
| Weight | 0.1 kg / Stück |