The Citel DLA2-12D3 is a 4-pole combined surge arrester utilizing diode and gas discharge tube technology, specifically designed for RS485 and RS232 applications. This plug-in unit features installation dimensions of 1 TE and weighs 0.1 kg per piece. Classified as a Type C2 and D1 arrester, it operates with a nominal voltage of 12 V and a C3 protection level of 30 V. The device handles a D1 lightning impulse current of 5 kA using a 10/350µs waveform, a C2 nominal discharge current of 5 kA, and a maximum discharge current of 20 kA based on an 8/20µs waveform. Additionally, the component offers a capacitance of less than 25 pF and a fast response time of under 1 ns. This model does not include a remote signaling contact.
For customized pricing and availability, please fill out ourcontact formor give us a call. We are dedicated to providing solutions that align with your specific requirements.
How can I access DLA2-12D3 catalogs, user manuals, technical documents, and PDFs?
Do you provide technical support for DLA2-12D3?
While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.
| Manufacturer | Citel |
|---|---|
| Country | |
| Part number | DLA2-12D3 |
| Inner Code | 3285544 |
| Product type | 4-pole combined surge arrester |
|---|---|
| Part number | 640211 |
| Catalogue title | DLA2-12D3 |
| Technology | Diode - gas discharge tube technology |
| Applications | RS485 and RS232 |
| Arrester type | Typ C2, D1 |
| Nominal voltage Un | 12 V |
| C3 protection level Up | 30 V |
| D1 lightning impulse current Iimp | 5 kA (10/350µs) |
| C2 nominal discharge current In | 5 kA (8/20μs) |
| Max. discharge current Imax | 20 kA (8/20μs) |
| Capacitance C | <25 pF |
| Response time | <1 ns |
| Installation dimensions | 1 TE, plug-in |
| Remote signaling contact | none |
| Weight | 0.1 kg / Stück |